Final edition of energy conservation by the advanced utilization of exhaust heat !!

Heat exchanger


 ◆ This type can be correspond to intense heat contraction because the radiation pipe that had the expansion
       function is adopted.
 ◆ Heat exchange of low pressure loss type that does not damage the performance of the hot-air generator that
      is concomitantly used.
 ◆ This type is designed compactly. But, the frequency of the maintenance by the clogging is reduced because
      the inside space is secured sufficient.

'Hot-air can be not circulated because
  the explosiveness solvent and plentiful
  vapor are included to exhaust gas', 'Thermal capacity wants to be enlarged
  a little more'.
These problems are solved.
     Basis example  
 

 

 

Average heat collection rate About 40%

High efficiency type HEXU-series  Specification list

         
                  《Heat exchange flow》
  
           

Model HEXU5 HEXU10 HEXU20
Specification Many pipe type heat exchanger
Max. use temp. 200゚C
Max. use air volume 5m3/min 10m3/min 20m3/min
Radiation side pressure loss 0.32kPa 0.25kPa 0.43kPa
Heat receiving side pressure loss 0.15kPa 0.18kPa 0.23kPa
Radiation & Heat receiving side resisting pressure Less than 2.96kPa
Bore of inlet & outlet of radiation & heat receiving side φ100 φ150 φ200
Material Heat exchange material and Outlet-Inlet flange : SUS,  Outside : ZAM
Price JPY 195,000 JPY 291,000 JPY 448,000

 

Average heat collection rate About 20%

Wide use type HEX-series  Specification list

         
       《Heat exchange flow》
    
           

Model HEX75 HEX100 HEX125
Specification Many pipe type heat exchanger
Max. use temp. 200゚C
Max. use air volume 4m3/min 6m3/min 12m3/min
Radiation side pressure loss 0.23kPa 0.23kPa 0.40kPa
Heat receiving side pressure loss 0.29kPa 0.16kPa 0.37kPa
Radiation & Heat receiving side resisting pressure Less than 2.96kPa
Bore of inlet & outlet of radiation & heat receiving side φ75 φ100 φ125
Material Heat exchange material and Outlet-Inlet flange : SUS,  Outside : ZAM
Price JPY 136,000 JPY 184,000 JPY226,000

 

Average heat collection rate About 35%

High temp. type HEX-HJ  Specification list

   ◆ This can collect the exhaust heat to Max. 500゚C.
          (With insulating material)

 
     
Model HEX-HJ
Specification Many pipe type heat exchanger
Max. use temp. 500゚C
Max. use air volume 1.5Nm3/min
Radiation side pressure loss 0.07kPa
Heat receiving side pressure loss 0.13kPa
Radiation & Heat receiving side resisting pressure Less than 2.96kPa
Bore of inlet & outlet of radiation & heat receiving side φ75
Material Heat exchange material and Outlet-Inlet flange, Outside  : SUS304,   Insulating material  : Glass wool
Price JPY 300,000

 